Comparing an ozone analyzer display with a generator specification or a laboratory report starts with the concentration unit. A value in ppmv expresses a gas composition, while mg/m³ and g/Nm³ describe ozone mass relative to a gas volume. Converting between them requires a stated temperature, absolute pressure and moisture basis. These details help buyers compare instruments and specify the reading required by a control system.
What the units describe
ppmv means parts per million by volume. For an ideal gas mixture, 1 ppmv corresponds to an ozone amount fraction of 1 µmol/mol. mg/m³ gives milligrams of ozone per cubic metre of gas at the stated conditions. g/Nm³ gives grams per cubic metre referred to defined normal conditions. The reference temperature and pressure belong alongside this unit in a specification.
For unchanged composition, the ideal-gas amount fraction stays the same when temperature or pressure changes. Mass per actual cubic metre changes because the number of gas molecules within that volume changes. The conversion follows the ideal-gas relation pV = nRT. IUPAC ideal-gas definition.
Convert ppmv into mg/m³
For an ideal gas mixture, use the following equations. Let c be the numerical concentration in ppmv and C be the numerical concentration in mg/m³.
C = c × M × P × 10−3 / (R × T)
c = C × R × T × 103 / (M × P)
Use M = 47.9982 g/mol for ozone, P in pascals of absolute pressure, T in kelvin and R = 8.314462618 Pa·m³/(mol·K). Convert Celsius to kelvin by adding 273.15. The factor 10−3 combines the parts-per-million fraction with the conversion from grams to milligrams. NIST ozone molecular weight. NIST molar gas constant.
| Temperature | Absolute pressure | mg/m³ per 1 ppmv ozone |
|---|---|---|
| 0 °C | 101.325 kPa | 2.14144 |
| 0 °C | 100 kPa | 2.11344 |
| 20 °C | 101.325 kPa | 1.99534 |
| 25 °C | 101.325 kPa | 1.96188 |
For example, 1,000 ppmv corresponds to approximately 1,962 mg/m³, or 1.962 g/m³, at 25 °C and 101.325 kPa absolute. These calculated digits describe the conversion factor. Measurement accuracy depends on the instrument and measurement conditions.
Why normal conditions change the factor
Always ask which conditions define Nm³. IUPAC specifies standard gas conditions as 0 °C and 100 kPa. Another reference used in gas-volume calculations is 0 °C and 101.325 kPa, equivalent to one standard atmosphere. The pressure difference changes the conversion factor by about 1.325%. A report should identify the reference explicitly. IUPAC standard conditions for gases.
Using a declared dry-gas reference of 0 °C and 101.325 kPa absolute, 1,000 ppmv becomes approximately 2.141 g/Nm³. On that basis, 1 g/Nm³ equals approximately 467 ppmv. The same ppmv value yields a different mass concentration when another reference is used.
For a direct calculation, use C (g/Nm³) = c (ppmv) × M × PN × 10−6 / (R × TN), where PN is the reference absolute pressure in pascals and TN is the reference temperature in kelvin.
Dividing mg/m³ by 1,000 changes milligrams into grams. To express the result in g/Nm³, first reconcile the volume conditions. For unchanged composition and the same moisture basis, an ideal-gas mass concentration converts between conditions using C2 = C1 × (P2/P1) × (T1/T2). Use matching mass units and absolute temperatures throughout.
Use absolute pressure and a consistent gas basis
Absolute pressure is measured from vacuum. A gauge pressure reading is relative to local atmospheric pressure, so Pabsolute = Pgauge + Patmospheric. Use the pressure at the measurement point for an actual-volume calculation, or the declared reference pressure for a normalized result. Confirm which pressure an analyzer uses in its compensation and reporting.
Also confirm whether concentrations are reported on a dry or wet basis. Water vapour contributes to the total gas quantity on a wet basis, so comparisons require consistent treatment of moisture. Where real-gas effects become significant, the calculation requires a suitable compressibility correction.
Gas concentration and dissolved ozone
For water, ppm commonly describes a mass ratio. In a dilute aqueous solution with density close to 1 kg/L, 1 ppm by mass is approximately 1 mg/L. Gas ppmv describes a different quantity, so applying the gas conversion factor to a dissolved-ozone reading gives an invalid comparison. Specify the liquid concentration unit and solution conditions when selecting a dissolved-ozone analyzer. USGS water-quality unit conversions.
Specify the reporting basis when choosing an analyzer
Provide the sample medium, required range and unit, measurement temperature, absolute pressure, moisture basis and reference conditions. Include the unit expected by your PLC or reporting system. Browse our ozone gas analyzers, review the MIC500-OZ and explore ozone measurement applications. Contact Zetron with your measurement requirements to discuss a suitable configuration.