Ozone Analyzer Selection Guide

Where will you take the sample?

Start with the measurement point on your process diagram. The same ozone system can have several points that answer different questions. A generator outlet reading helps assess gas output. A dissolved reading downstream of the contactor helps assess the residual in water. A reading in an exhaust duct describes that stream at its sampling point. List the points you need to monitor and the decisions each reading will support. That list is the basis for comparing instruments.

Choose a gas or dissolved ozone analyzer

For process gas, compare the ozone gas analyzer range. Supply the carrier gas composition, expected moisture, temperature, pressure, available flow and any other constituents that could affect the measurement. Give these details for normal operation and for the conditions during startup or a change of operating mode. Identify the diagram location and the distance to the proposed instrument mounting point.

For ozone dissolved in a liquid, compare the dissolved ozone analyzer range. Specify the water source, sample pressure and temperature, and whether the stream may contain bubbles, suspended solids or other contaminants. State how the sample will reach the instrument and where it can drain or return. For an existing system, identify fittings, available space and the current sampling arrangement.

Specify the operating range and its basis

Provide the lowest concentration you need to resolve, the normal range and the highest reading of interest. If a control system has alarm or control setpoints, include those values and their units as part of the specification. State whether the values come from an existing analyzer, a generator datasheet or a design requirement. This helps the supplier check that the requested configuration covers both the signals you care about and the upper end of the range.

When a gas range uses g/Nm³, supply the reference temperature, absolute pressure and dry or wet basis. When it uses ppmv, confirm that the specification is on a volume basis. On a water line, enter the liquid concentration units separately. The ozone concentration conversion guide explains which inputs are needed to compare gas ranges in different units.

Compare instruments by installation format

For a wall-mounted gas installation, review the MIC500-OZ and MIC100OZ. Check enclosure dimensions, display and connectors against the space and access available. For an indoor equipment layout, compare the compact MIC300OZ, the 19-inch rack-mounted MIC600OZ and the benchtop PTM600-OZ. Specify any ventilation, maintenance clearances, cable routing and operating environment requirements before approving the layout.

For water measurements, review the OZ-150W, OZ-180W and OZ-300W specification pages. Ask for a written comparison of the quoted ranges, sample connections, display, outputs and included accessories for your liquid stream. Use the same set of sample conditions when requesting each quote so the proposed configurations can be compared directly.

Check sample handling, controls and service access

Send a drawing showing the sample point, instrument location and return or exhaust path. Note whether the sample reaches the cabinet under pressure or needs an extraction arrangement. If moisture, particles or bubbles are likely, ask how the proposed sample handling will affect measurement at your point. Request a list of all components included in the quote and identify which items your installation team must provide.

Specify the electrical supply, local display needs, the expected analog signal and the serial protocol supported by your control system. Ask how the analog span will correspond to the configured instrument range and how faults are signaled. Describe whether the instrument has to integrate into an existing PLC or SCADA system. The UV absorption guide explains zeroing and the conditions that can affect the reading.

Questions to include in a request for quotation

What should be in the quote?

Ask the supplier to state the exact model and configured range, concentration units and reference conditions, sample inlet requirements, output options, included accessories and required site utilities. Request drawings and instructions for the configuration you will receive. For a replacement instrument, include the current model, mounting dimensions, serial number if available and a photo of the sample connections.

What if the sample conditions are still being designed?

Send the process stage, known concentration range, sample medium and a preliminary diagram. Include which inputs are estimates and the expected date for fixing the design. You can use the ozone applications overview to find a similar measurement point and send your project details to Zetron for a configuration review.